Total Power Draw
48.2 MW
โฒ 3.4% vs yesterday
PUE Average
1.38
โฒ 0.04 improvement
UPS Uptime
99.97%
โ 30 day avg
Active Alerts
5
โผ 2 since yesterday
AI Workload %
34%
โฒ 12% YoY
Carbon Intensity
142 g/kWh
โฒ Better by 8%
Power Consumption Trends โ All Sites
MW ยท 24-hour rolling average per facility
Load Distribution
By infrastructure type
Site PUE Comparison
Power Usage Effectiveness
Capacity Utilization
Current vs max rated
Energy Sources
Grid vs renewable mix
Site Status Summary
View All โ
| Site ID | Location | Power Draw (MW) | Capacity % | PUE | UPS Status | Temp (ยฐC) | Status |
|---|---|---|---|---|---|---|---|
| DC-EAST-01 | Virginia, USA | 14.8 | 74% | 1.32 | Online | 21.4 | Nominal |
| DC-WEST-02 | Oregon, USA | 11.2 | 61% | 1.41 | Warning | 22.1 | Advisory |
| DC-EU-03 | Frankfurt, DE | 12.6 | 68% | 1.38 | Online | 20.8 | Nominal |
| DC-APAC-04 | Singapore | 9.6 | 55% | 1.45 | Online | 23.2 | Nominal |
Total Switchgear
24
โ Units online
Grid Voltage
480 V
โ Stable ยฑ0.2%
Peak Demand
52.1 MW
โผ from 14:32 today
Fault Events
2
โผ 1 active fault
HV Systems
8 units
โ AI-era 1kV+ systems
Power Factor
0.96
โฒ Excellent
Real-Time Power Draw โ Per Circuit
kW per distribution circuit ยท 15-min intervals
Voltage Stability
All phases ยท last 24h
Switchgear Status
Operational health per unit
MV-SWG-01
94%
MV-SWG-02
87%
HV-SWG-01
72%
HV-SWG-02
98%
XFMR-01
61%
XFMR-02
91%
Power Events (30 Days)
Incidents by type
Avg Cold Aisle
18.2ยฐC
โ ASHRAE A1 compliant
Avg Hot Aisle
35.8ยฐC
โฒ 1.2ยฐC vs yesterday
CRAC Units
36
โ 34 active / 2 standby
Cooling PUE
0.38
โฒ Improved 0.02
Hotspot Alerts
1
โผ Row G, Rack 14
WUE
0.91 L/kWh
โฒ Industry leading
Temperature Map โ DC-EAST-01 Floor Plan
24h thermal heatmap by rack row (AโH) and hour
Row
00:0006:0012:0018:0023:00
Cool
Hot
Cooling Load vs IT Load
Efficiency correlation
Temperature Trends
Inlet/outlet delta ยท 7 days
CRAC Unit Performance
Load and efficiency by unit
Total UPS Units
48
โ 46 online, 2 maintenance
Avg Battery Health
87%
โ Fleet average
Low Battery Units
3
โผ <75% capacity
Backup Runtime
12.4 min
โ At current load
Transfer Tests Passed
100%
โ Last 30 days
Total Capacity
2.4 MVA
โฒ 78% utilized
Battery Health Distribution
UPS units by health band
UPS Load vs Runtime
Load factor impact on backup time
UPS Fleet โ Detailed Status
All units ยท real-time data
46 OK
2 Warning
1 Critical
| Unit ID | Site | Model | Capacity | Load % | Battery % | Runtime | Last Test | Status |
|---|---|---|---|---|---|---|---|---|
| UPS-A01 | DC-EAST-01 | Galaxy VX 500kVA | 500 kVA | 72% | 96% | 18 min | 2025-01-15 | Online |
| UPS-A02 | DC-EAST-01 | Galaxy VX 500kVA | 500 kVA | 68% | 91% | 16 min | 2025-01-15 | Online |
| UPS-B07 | DC-WEST-02 | Symmetra PX 250kVA | 250 kVA | 81% | 68% | 8 min | 2025-01-10 | Critical |
| UPS-B08 | DC-WEST-02 | Symmetra PX 250kVA | 250 kVA | 74% | 74% | 10 min | 2025-01-10 | Warning |
| UPS-C01 | DC-EU-03 | Galaxy VS 160kVA | 160 kVA | 55% | 99% | 22 min | 2025-01-20 | Online |
| UPS-D01 | DC-APAC-04 | Easy UPS 3S | 120 kVA | 60% | 88% | 15 min | 2025-01-18 | Online |
Total PDUs
312
โ Rack-level distribution
Avg Load
62%
โ Of rated capacity
Overloaded
4
โผ >85% threshold
Metered PDUs
98%
โฒ Smart metering
Phase Imbalance
3.2%
โฒ Acceptable
Outlets Utilized
78%
โ 3,744/4,800
PDU Load Distribution โ All Sites
% load per PDU unit ยท sorted ascending
Phase Balance
3-phase distribution
Top 10 PDUs by Load
| PDU ID | Row | Rack | Type | L1 (A) | L2 (A) | L3 (A) | Total kW | Load % | Status |
|---|---|---|---|---|---|---|---|---|---|
| PDU-G14-A | G | 14 | 3-Phase 30A | 28.1 | 27.8 | 29.2 | 19.8 | 93% | Overload |
| PDU-F09-B | F | 9 | 3-Phase 30A | 25.4 | 26.1 | 27.0 | 17.2 | 88% | Overload |
| PDU-H02-A | H | 2 | 3-Phase 30A | 24.8 | 25.2 | 24.6 | 16.6 | 82% | Warning |
| PDU-A01-A | A | 1 | 3-Phase 30A | 22.1 | 21.8 | 22.4 | 14.8 | 74% | Normal |
| PDU-B05-A | B | 5 | 3-Phase 30A | 20.6 | 20.1 | 21.0 | 13.9 | 69% | Normal |
Generator Units
16
โ Diesel + NG backup
Fuel Level Avg
84%
โ Fleet average
Low Fuel Alert
2
โผ Gen-04, Gen-11
Last Test Run
3 days ago
โ Weekly schedule
Rated Capacity
120 MW
โ N+1 redundancy
Transfer Time
8.2 ms
โฒ Avg switchover
Generator Fuel Levels โ All Units
% capacity with 72-hour runtime projection
Generator Health
By site and status
Generator Fleet Status
| Unit | Site | Fuel Type | Rated MW | Fuel % | Runtime (hrs) | Hours Since Service | Next Test | Status |
|---|---|---|---|---|---|---|---|---|
| GEN-01 | DC-EAST-01 | Diesel | 8 | 92% | 110h | 142h | Jan 22 | Ready |
| GEN-04 | DC-EAST-01 | Diesel | 8 | 38% | 46h | 98h | Jan 22 | Low Fuel |
| GEN-07 | DC-WEST-02 | Natural Gas | 10 | N/A | Unlimited | 210h | Jan 24 | Ready |
| GEN-11 | DC-EU-03 | Diesel | 7 | 41% | 58h | 165h | Jan 26 | Low Fuel |
| GEN-14 | DC-APAC-04 | Diesel | 6 | 87% | 96h | 88h | Jan 25 | Ready |
GPU Clusters
12
โฒ +4 NVIDIA H100 clusters
GPU Power Draw
16.4 MW
โฒ 34% of total load
Rack Density (AI)
42 kW/rack
โฒ 3ร standard density
GPU Utilization
78%
โฒ 12% vs last quarter
Liquid Cooling
64%
โฒ AI racks on direct liquid
AI Revenue Share
41%
โฒ +18% YoY
AI Workload Power Growth Forecast
MW ยท actual vs projection through 2026
GPU Model Mix
Fleet composition
Power per GPU Model
kW draw vs compute output
AI vs Standard Workload Split
Monthly trend
Global PUE
1.38
โฒ Target: 1.30 by 2026
Renewable %
67%
โฒ +8% this year
Carbon Saved
12.4 kt COโ
โฒ vs 2022 baseline
Energy Cost
$4.2 M/mo
โฒ -6% vs prev month
WUE
0.91 L/kWh
โ Best-in-class avg
Stranded Power
8.2%
โฒ Down from 14%
PUE Trend โ 12 Months
All sites ยท with industry benchmark
Energy Source Mix
Current month
Monthly Energy Cost
$ million ยท 12 months
Carbon Emissions Reduction
kt COโ ยท vs 2022 baseline
Critical
1
โ Requires immediate action
Warnings
4
โ Monitor & schedule
Info Events
18
โ Last 24 hours
Resolved Today
7
โฒ MTTR: 22min avg
Alert Volume โ Last 7 Days
By severity ยท daily breakdown
Alerts by Category
Active Alert Feed
1 Critical
4 Warning
CRIT
14 min ago
WARN
1h 22min ago
WARN
2h 05min ago
WARN
3h 48min ago
WARN
5h 12min ago
INFO
8h ago
INFO
11h ago
Active Initiatives
9
โ Strategic programs
On Schedule
6
โ 67%
At Risk
2
โ Supply chain delays
Investment
$2.8 B
โ 2024โ2026 capex
Initiative Progress Tracker
Strategic programs ยท % complete
Budget vs Spend
$M per initiative category
Milestone Timeline โ Q1 2025 through Q4 2026
Q4 2024 โ
DC-EAST-01 HV Upgrade โ COMPLETE
480V โ 1,000V high-density power infrastructure deployed for AI workloads ยท NVIDIA partnership activated
Q1 2025 โ
UPS Fleet Modernization Phase 1 โ COMPLETE
Replaced 12 legacy units with Galaxy VX series ยท Improved reliability to 99.97% uptime
Q2 2025 โ
DC-WEST-02 Liquid Cooling Expansion โ IN PROGRESS
Direct liquid cooling for GPU racks ยท 68% complete ยท On schedule for June delivery
Q2 2025 โ
Smart PDU Rollout (312 Units) โ AT RISK
IoT-enabled metered PDUs ยท 42% complete ยท Supply chain delay pushing delivery to Q3
Q3 2025
DC-EU-03 Renewable Energy Transition
100% renewable PPA target ยท Solar + wind procurement agreements ยท 15% complete
Q4 2025
AI-Era Switchgear Deployment
High-voltage switchgear for 100kW+ GPU rack clusters ยท NVIDIA HGX H200 readiness
Q2 2026
DC-APAC-05 Greenfield Build
New 60MW AI-optimized facility in Tokyo ยท 100% renewable ยท liquid cooling native